Parameter Measurement | Current |
Voltage | |
Active/Reactive/Apparent Power | |
Power Factor | |
Frequency | |
Phase and Neutral Line | |
Wire Line and Phase Line | |
3 Phases and Single Phase | |
3 Phases and Single Phase | |
Energy Measurement | Input/Output Active Energy |
Input/Output Reactive Energy | |
Apparent Energy | |
1 Channel Pulse Output | |
1 Channel Pulse Output | |
Demand Statistics | Current |
Active/Reactive/Apparent Power | |
Current Value and Max. | |
Current Value and Max. | |
Max and Min | Record the max, min and time of all measurement parameters |
Restoration Rate | 8 Restoration Stages; 4 Restoration Rate can be set |
Power Quality | Harmonic Distortion |
31 times Harmonic Analysis | |
Current and Voltage | |
Current and Voltage | |
Communication Protocol | MODBUS-RTU |
Display | STN LCD Display with big screen |
Real-Time Clock | |
Year/Month/ Day/Hour/Minute/Second | |
Relay Output Module | 2 Channels Relay Output |
Programmable Alarm Setting of exceeding the limit | |
Remote Control | |
Analog Input and Output Module | 1 Channel Analog Input Measurement for 4-20mA DC |
1 Channel Analog Input Measurement for 0-5V DC | |
2 Channels Analog Output for 4-20mA DC |
Electrical characteristics | ||
Measure Type | 3P3W AC system, 3P4W AC system | |
Sampling rate | 128 points per cycle | |
Data refresh rate | 1S | |
Measure accuracy | Current | ±0.2%FS |
Voltage | ±0.2%FS | |
Power | 0.5S | |
Frequency | ±0.001Hz | |
Active Energy | 0.5S | |
Reactive Energy | 1.0S | |
DC input(AI) | 0.5% FS | |
DC output(AO) | 0.5% FS | |
Input voltage characteristics | Measure Voltage | 3 *220/380V(Directly input) |
3 * 57.7/100V(PT secondary side) | ||
Allowed overload capability | 1.2 times / continuous | |
input resistance | 300KΩ | |
Input current characteristics | Measure current | 5A (CT Secondary side)Or 1A (CT Secondary side) |
Allowed overload capability | 1.2 times / continuous | |
input resistance | <0.1Ω | |
Binary input | Working voltage | 12~24 VDC |
input resistance | 12KΩ | |
Isolation voltage | 2KV | |
Relay Output | Node type | Mechanical contact |
Node capability | 220 VAC/5A、30 VDC/5A | |
4-20mA DC input measurement | Measure current | 4-20mA |
Allowed overload capability | 1.2 times / continuous | |
input resistance | 10Ω | |
Isolation voltage | 2KV | |
0-5V DC input measurement | Measure Voltage | 0-5V |
Allowed overload capability | 1.2 times / continuous | |
input resistance | 12.5KΩ | |
Isolation voltage | 2KV | |
4-20mA DC output | Open-circuit Voltage | 15VDC |
Load capability | ≤600Ω | |
Isolation voltage | 2KV | |
Power supply | AC | 100~240 VAC/45-65Hz |
DC | 100~375 VDC | |
Power consumption | < 3W | |
Mechanical performance | ||
Weight | 0.5kg | |
IP Protection Level | Meter Panel IP52, Meter Host IP30 | |
Dimension | Host | 96 X 96 X 72 mm |
Host+modules | 96 X 96 X 120 mm | |
Working temperature | Display screen | -20~70℃ |
Meter | -25~70℃ | |
storage temperature | Meter+display screen | -40~85℃ |
Relative humidity | 5% - 90%RH, No condensation | |
EMC | ||
Antistatic discharge interference | IEC 61000-4-2,Level 4 | |
Anti-fast transient group pulse | IEC 61000-4-4,Level 4 | |
Anti-surge | IEC 61000-4-5,Level 3 | |
Resistance to power frequency magnetic field | IEC 61000-4-8,Level 3 | |
Electrical insulation performance | ||
Insulation resistance | GB/T13729,>50MΩ | |
Power frequency withstand voltage | GB/T13729,AC 2KV 50Hz /1min | |
Impulse voltage | GB/T13729,5KV,1.2/50us |
Model specification:PMC200S-①-②-③-④-⑤ | |
①Model code: | |
1 | 57.7/100V Rated measurement voltage,5A Rated measurement current。 |
2 | 57.7/100V Rated measurement voltage,1A Rated measurement current。 |
3 | 220/380V Rated measurement voltage,5A Rated measurement current。 |
4 | 220/380V Rated measurement voltage,1A Rated measurement current。 |
②Model code: | |
1 | Power supply:85~264 VAC/45-65Hz,100~300 VDC 。 |
③Model code: | |
0 | Without DI |
4 | 4 Channels DI |
④Model code: | |
0 | Without relay output |
1 | Optional 1 channel relay output(RL1+、RL1- port) |
2 | Optional 2 channels relay output |
⑤Model code: | |
ab | ab is a 2 integer,a means AI01 port optional for AI/AO modules, b means AI02 port optional for AI/AO 0 –none 1 - 0-5V DC analog input measure(AI) 2 - 4-20mA DC analog input measure(AI) 3 - 4-20mA DC analog output(AO) For example: ab = 00,Means AI 01 port is not equipped with AI/AO module, AI02 port is not equipped with AI/AO module ab = 12,Means AI01 port is equipped with 0-5V DC analog input measure AI/AO module, AI02 port is equipped with 4-20mA DC analog input measure AI/AO module |