● | Universal Relay Test Applications |
● | 10 Channels (6x35A & 4x310V) outputs, Each output channels are independent and simultaneous control of magnitude, Phase angle and frequency values, able to inject DC, AC sine wave and up to 60x harmonics. |
● | Variable battery simulator, DC 0-350V, 140Watts max. |
● | Transient play back up to 3KHz |
● | Fully function KRT software testing modules |
● | Graphical test modules and templates for testing of various relays |
● | Quick relay testing facility in Manual mode |
● | Shot/Search/Check, Point & Click testing |
● | RIO/XRIO import & export facility |
● | Switch on to fault test(SOTF) |
● | Power system model for dynamic testing |
● | Online Vector display |
● | Automatic test results assume |
● | Automatic test report creation |
● | Inbuilt GPS sync end-to-end testing |
● | Anti-clipping detect, Wrong wiring connect alarm and self-protect, overload and overheat protection |
● | 3-Years guarantee of free repair and life-long maintenance |
● | Lightweight, <19.5Kg |
● | Free software upgrade |
● | Energy meter calibration (Mechanical & Electronic meters) |
Items | ANSI® No. |
Distance protection relay | 21 |
Synchronising or synchronism-check relays | 25 |
Undervoltage relays | 27 |
Directional Power relays | 32 |
Undercurrent or underpower relays | 37 |
Negative sequence overcurrent relays | 46 |
Overcurrent/ground fault relays | 50 |
Inverse time overcurrent/ground fault relays | 51 |
Power factor relays | 55 |
Overvoltage relays | 59 |
Voltage or current balance relays | 60 |
Directional overcurrent relays | 67 |
Directional ground fault relays | 67N |
DC overcurrent relays | 76 |
Phase-angle measuring or out-of-step protection relays | 78 |
Automatic reclosing devices | 79 |
Frequency relays | 81 |
Motor overload protection relays | 86 |
Differential protection relays | 87 |
Directional voltage relays | 91 |
Voltage and power directional relays | 92 |
Tripping relays | 94 |
Voltage regulating relays | |
Overimpedance relays, Z> | |
Underimpedance relays, Z | |
Time-delay relays |
Voltage Outputs | ||
Output Range & Power | 4×310 V ac (L-N) | 124 VA max each |
3×350 V dc (L-N) | 140 W max each | |
Accuracy | <0.02%Rd+0.005Rg Typ. <0.05%Rd+0.01Rg Guar. |
|
±10mV @ <5V dc ±0.5% @ ≥5V dc |
||
Voltage Range | Range I : 30V | |
Range II : 310V | ||
Automatic Range | ||
DC Offset | <10mV Typ./ <60mV Guar | |
Resolution | 1mV | |
Distortion | <0.015%Typ. / <0.05% Guar. | |
Current Outputs | ||
Output Range & Power | 6×35A ac (L-N) | 450 VA max each |
3×70A ac (2L-N) | 850 VA max each | |
1×100A ac (6L-N) | 1200 VA max | |
3×20A dc (L-N) | 300W max each | |
Accuracy | <0.03%Rd+0.02Rg Typ. <0.1%Rd+0.05Rg Guar. |
|
±5mA @ <1A dc ±0.5% @ ≥1A dc |
||
Current Range | Range I: 3A | |
Range II: 35A | ||
Automatic Range | ||
DC Offset | <3mA Typ./ <10mA Guar | |
Resolution | 1mA | |
Distortion | <0.025%Typ. / <0.07% Guar. | |
Frequency & Phase Angle | ||
Frequency Range | DC~1KHz, 3KHz transient | |
Frequency Accuracy | ±0.5ppm | |
Frequency Resolution | 0.001 Hz | |
Phase Range | -360°~360° | |
Phase Accuracy | <0.02° Typ. / <0.1° Guar. 50/60Hz | |
Phase Resolution | 0.001° | |
Aux. DC Voltage Source (Battery simulator) | ||
Range | 0~350V @ 140W max | |
Accuracy | 0.5%Rg Guar. | |
Binary Input | ||
Quantity | 8pairs | |
Type | wet/dry, up to 300Vdc max input | |
Time resolution | 10us | |
Sampling Rate | 10KHz | |
Debounce time | 0~25ms (Software Controlled) | |
Time range | Infinite | |
Time errors | ±1ms @ ≤1s, ±0.1% @ >1s | |
Galvanic isolation | Isolated each pairs | |
Binary Output (Relay Type) | ||
Quantity | 4pairs | |
Type | Potential free relay contacts, software controlled | |
Break Capacity AC | Vmax: 400Vac / Imax:8A / Pmax:2500VA | |
Break Capacity DC | Vmax: 300Vdc / Imax:5A / Pmax:150W | |
Binary Output (Semiconductor Type) | ||
Quantity | 4pairs | |
Type: | Open-collector, Combination type male | |
Break Capacity DC | 5~15Vdc / 5mA, 10mA max | |
Response time: | 100us | |
Synchronization | ||
Synchronization Mode | GPS, SMA type antenna connector | |
Power supply & Environment | ||
Nominal Input Voltage | 110V/220/230V ac, Appointed | |
Permissible Input Voltage | 85~264Vac, 125~350VDC, auto-protective | |
Nominal Frequency | 50/60Hz | |
Permissible Frequency | 45Hz~65Hz | |
Power Consumption | 1500 VA max | |
Connection Type | Standard AC socket 60320 | |
Operating Temperature | -10℃~55℃ | |
Storage Temperature | -20℃~70℃ | |
Humidity | <95%RH, non-condensing | |
Others | ||
PC Connection | RJ45 Ethernet, 10/100M | |
Grounding Terminal | 4mm banana socket | |
Weight | 19.5 Kg | |
Dimensions(W x D x H) | 360×450×140(mm) |
Energy Meter Calibration Hardware is ready, to be active | |
Sensor Usage | Mechanical meters / Electronic meters |
Sensor Output | High lever:>4.5V, Low level:<0.2V |
Pulse Input | 1 pulse input port, 5Vdc high level valid only. |
Pulse Range | 500KHz pulse input Max. |
Pulse Output | 1 Transistor output, Open-collector, 5Vdc/5mA |
Model | Current Outputs | Voltage Outputs | Optional Function |
K3066i | 6×35A @ 450VA max 3×70A @ 850VA max |
7×310V @ 90VA max | ● Energy Meter Cal. |
K3063i | 6×35A @ 450VA max 3×70A @ 850VA max |
4×310V @ 124VA max | |
K3030i | 3×35A @ 450VA max | 4×310V @ 124VA max |