AC current source | |
Amplitude & Power | 6×35A @ 424VA max each; 3×70A @ 670VA max each; |
Accuracy | <0.015%Rd+0.005%Rg Typ. <0.04%Rd+0.01%Rg Guar. |
Range | Range I: 3A Range II: 35A Automatic Range |
DC Offset | <3mA Typ./ <10mA Guar |
Resolution | 1mA |
Distortion | <0.025%Typ. / <0.07% Guar. |
Ascends/Descent response | <100us |
DC Current source | |
Amplitude & Power | 3×20A @ 400W max |
Accuracy | ±5mA @ <1A ±0.2% @ ≥1A |
Ascends/Descent response | <100us |
AC voltage source | |
Amplitude & Power | 6×310V @ 105VA max each |
Accuracy | <0.015%Rd+0.005Rg Typ. <0.04%Rd+0.01Rg Guar. |
Range | Range I: 30V Range II: 310V Automatic Range |
DC Offset | <10mV Typ./ <60mV Guar |
Resolution | 1mV |
Distortion | <0.015%Typ. / <0.05% Guar. |
Ascends/Descent response | <100us |
DC Voltage source | |
Amplitude & Power | 6×350V @ 100W max 3×700V @ 150W max |
Accuracy | ±10mV @ <5V ±0.2% @ ≥5V |
Ascends/Descent response | <100us |
Frequency & Phase Angle | |
Frequency Range | DC ~ 1000Hz, 3000Hz transient |
Frequency Accuracy | ±0.5ppm |
Frequency Resolution | 0.001Hz |
Phase Range | -360°~360° |
Phase Accuracy | <0.02° Typ. / <0.1° Guar. 50/60Hz |
Phase Resolution | 0.001° |
Auxiliary DC Supply (Battery Simulator) | |
Range | 8 ~ 60Vdc (Max Load Current 1.16A) Accuracy<2% 60 ~ 120Vdc (Max Load Current 0.58A) Accuracy<1% 120 ~ 350Vdc (Max Load Current 0.2A) Accuracy<0.5% |
Power | >69W max |
Resolution | 10mV |
Protection | Short-circuit protection |
Overload Protection | Yes |
Isolation | Isolated from other terminal |
Binary input | |
Electrical isolation | 10 pairs of electrical isolated each |
Input impedance | 5 kΩ…13kΩ(Empty contact) |
Input feature | 0 V~300Vdc Or dry contact (Binary 1~4 inputs turn over potential can be programmable) |
Sampling Rate | 10kHz |
Time resolution | 10us |
Time measurement range | infinity |
Time accuracy | ±1ms @ <1s ±0.1% @ ≥1s |
Debounce time | 0~25ms (Software controlled) |
Binary Output | |
Quantity | 4 pairs |
Type | Fast speed transistor, programmable software control |
AC break capacity | Vmax:250V(AC)/ Imax:0.5A |
DC break capacity | Vmax:250V(DC)/ Imax:0.5A |
Electrical isolation | All pairs isolated |
Time Synchronization | |
Satellite synchronization | 1 × SMA,Use for GPS antenna interface Support GPS and Beidou Satellite |
Fiber IRIG-B | 2 × ST,1 for transmission, 1 for receiving |
Electric IRIG-B | 1 × 6Pin 5.08mm phoenix terminal 1 for transmission, 1 for receiving |
External trigger synchronization | 1 × 4Pin 5.08mm phoenix terminal external trigger input + external trigger output |
Sync error | <10us |
Communication interface | |
Ethernet | 2 × RJ45 ,10/100M |
WIFI | Inbuilt WIFI DHCP service |
Serial port | 1 × RS232 |
USB | 2 × USB2 |
Weight & Size | |
Size | 390mm×256mm×140mm |
Weight | 10kg |
Power supply | |
Nominal voltage | 220V/110V (AC) |
Allowable voltage | 85 - 265 VAC ;127V~350V(DC) |
Nominal Frequency | 50Hz |
Allowable Frequency | 47-63Hz |
Current | 10A max |
Power Consumption | 1200VA max |
Connection Type | Standard AC socket 60320 |
Working environment | |
Operating temperature | -10~+55 ℃ |
Relative humidity | 5~95%,Non-condensation |
Storage temperature | -20℃ ~ +70℃ |
Atmospheric pressure | 80kPa~110 kPa(altitude 2000m or lower) |
● | Fully complying IEC61850 Sampling value and GOOSE; (IEC61850-9-1, IEC61850-9-2/(LE), IEC60044-7/8) |
● | Able to simultaneously output sampling value and analog signals, or subscriber and publish GOOSE message and relay contact binary I/O function. |
● | Up to 36 sampling value channels can be mapped. |
Fiber port (LC type) | |
Type | 100Base-FX (100Mbit,Fiber, full duplex) |
Port Number | 8 Pairs |
Cable model | 62.5/125μm(Multiple-mode fiber, orange) |
Wave length | 1310nm |
Transmission distance | > 1Km |
Status indication | SPD Green (lights): active connection Link\AcT Yellow (blinking): data exchange |
Low-level signal output | |
Output channels | 10 channels, 8 Voltage outputs + 2 Current outputs |
Output port type | Phoenix terminal |
Output range | 8x0~8Vrms; 2x0~20mA |
Accuracy | (0.01~0.8 Vrms/0~2mA):<0.05% Typ. / <0.1% Guar. (0.8~8 Vrms/2~20mA): <0.02% Typ. / <0.05% Guar. |
Resolution | 250µV |
Harmonic(THD%) | < 0.05% Typ. / <0.1% Guar. |
Frequency range | DC~1.0kHz, transient 3KHz |
Frequency accuracy | 0.002%(Normal frequency) |
Frequency resolution | 0.001Hz |
Phase range | 0~359.9° |
Phase accuracy | <0.02°,50/60Hz |
Phase resolution | ±0.001° |
DC Measurement Input | ||
Voltage Input | Range | 0~±10V dc |
Max Input | ±11V dc | |
Accuracy | Accuracy <0.05% rg Typ. <0.02% rg Guar. | |
Input Impedance | 1M ohm | |
Current Input | Range | 0~±1mA / 1~±20mA, auto range |
Max Input | 600mA | |
Accuracy | Accuracy <0.05% rg Typ. <0.02% rg Guar. | |
Input Impedance | 15 ohm |
Energy Meter Calibration | |
Sensor Usage | Mechanical meters / Electronic meters |
Sensor Output | High lever:>4.5V, Low level:<0.2V |
Pulse Input | 1 pulse input port, 5Vdc high level valid only. |
Pulse Range | 500KHz pulse input Max. |
Pulse Output | 1 Transistor output, Open-collector, 5Vdc/5mA |